DC/DC Converter
•
•
•
•
•
TES 3WI Series, 3 Watt
Ultra-wide 4:1 input voltage range
I/O isolation 1500 VDC
Operating temp. range –40°C to +70°C
Short circuit protection
Input filter to meet EN 55032,
conducted class A
•
•
•
Remote On/Off
•
•
Available in tape & reel package
High accuracy of pin co-planarity
Qualified for leadfree reflow solder
process according IPC/JEDEC
J-STD-020E
The TES 3WI series is a family of high performance 3W DC/DC-converter modules in a low profile SMD package with compact dimensions. The 14 modules
feature ultrawide 4:1 input ranges with tightly regulated output voltage. High
efficiency allows an operating temperature range of –40°C to +70°C at full
load. Further features are built-in EMI-filter to meet EN 55032 conducted class
A without external components and remote On/Off control. The products comply with IPC J-STD-020E and are qualified for high temperature lead-free reflow
solder process.
3-year product warranty
Models
Order Code
Input Voltage
Range
TES 3-2410WI
TES 3-2411WI
TES 3-2412WI
TES 3-2413WI
TES 3-2421WI
TES 3-2422WI
TES 3-2423WI
TES 3-4810WI
TES 3-4811WI
TES 3-4812WI
TES 3-4813WI
TES 3-4821WI
TES 3-4822WI
TES 3-4823WI
www.tracopower.com
9 - 36 VDC
(24 VDC nom.)
18 - 75 VDC
(48 VDC nom.)
Output 1
Output 2
Vnom
Imax
3.3 VDC
5 VDC
12 VDC
15 VDC
+5 VDC
+12 VDC
+15 VDC
3.3 VDC
5 VDC
12 VDC
15 VDC
+5 VDC
+12 VDC
+15 VDC
750 mA
600 mA
250 mA
200 mA
300 mA
125 mA
100 mA
750 mA
600 mA
250 mA
200 mA
300 mA
125 mA
100 mA
September 20, 2023
Vnom
Efficiency
Imax
–5 VDC
–12 VDC
–15 VDC
300 mA
125 mA
100 mA
–5 VDC
–12 VDC
–15 VDC
300 mA
125 mA
100 mA
typ.
75 %
79 %
81 %
81 %
78 %
81 %
81 %
76 %
80 %
83 %
83 %
80 %
83 %
83 %
Page 1 / 4
TES 3WI Series, 3 Watt
Input Specifications
Input Current
- At no load
24 Vin models:
48 Vin models:
24 Vin models:
48 Vin models:
24 Vin models:
48 Vin models:
24 Vin models:
48 Vin models:
24 Vin models:
48 Vin models:
24 Vin models:
48 Vin models:
- At full load
Surge Voltage
Start-up Voltage
Under Voltage Lockout
Reflected Ripple Current
Recommended Input Fuse
Short Circuit Input Power
20 mA typ.
10 mA typ.
155 mA typ.
75 mA typ.
50 VDC max. (1 s max.)
100 VDC max. (1 s max.)
4.5 VDC min. / 6 VDC typ. / 8.5 VDC max.
8.5 VDC min. / 12 VDC typ. / 17 VDC max.
8 VDC max.
16 VDC max.
10 mAp-p typ.
5 mAp-p typ.
(The need of an external fuse has to be assessed
in the final application.)
2 W max.
Output Specifications
Voltage Set Accuracy
Regulation
- Input Variation (Vmin - Vmax)
- Load Variation (10 - 100%)
Ripple and Noise
Capacitive Load
- Voltage Balance
(symmetrical load)
- 20 MHz Bandwidth
- single output
- dual output
±1% max.
0.5% max.
0.5% max.
1% max.
1% max. (Output 1)
1% max. (Output 2)
dual output models: 2% max.
single output models:
dual output models:
single output models:
dual output models:
3.3 Vout models:
5 Vout models:
12 Vout models:
15 Vout models:
5 / -5 Vout models:
12 / -12 Vout models:
15 / -15 Vout models:
Minimum Load
Temperature Coefficient
Start-up Time
Short Circuit Protection
Overload Protection
Output Current Limitation
Transient Response
- Response Deviation
- Response Time
75 mVp-p max.
3'000 µF max.
3'000 µF max.
3'000 µF max.
3'000 µF max.
180 / 180 µF max.
180 / 180 µF max.
180 / 180 µF max.
10 % of Iout max.
(Operation at lower load will not damage the
converter, but it may not meet all specifications)
±0.02 %/K max.
16 ms max.
Continuous, Automatic recovery
Foldback Mode
120% min. of Iout max.
2% typ. / 6% max. (75% to 100% Load Step)
150 µs typ. / 500 µs max. (75% to 100% Load
Step)
EMC Specifications
EMI Emissions
EN 55032 class A (internal filter)
FCC Part 15 class A (internal filter)
EN 55032 class A (internal filter)
FCC Part 15 class A (internal filter)
- Conducted Emissions
- Radiated Emissions
General Specifications
Relative Humidity
95% max. (non condensing)
All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated.
www.tracopower.com
September 20, 2023
Page 2 / 4
TES 3WI Series, 3 Watt
Temperature Ranges
Power Derating
- Operating Temperature
- Case Temperature
- Storage Temperature
- High Temperature
Cooling System
Remote Control
- Voltage Controlled Remote
- Off Idle Input Current
- Remote Pin Input Current
Switching Frequency
Insulation System
Isolation Test Voltage
Isolation Resistance
Isolation Capacitance
Reliability
Moisture Sensitivity (MSL)
Washing Process
- Input to Output, 60 s
- Input to Output, 500 VDC
- Input to Output, 100 kHz, 1 V
- Calculated MTBF
Housing Material
Pin Material
Pin Foundation Plating
Pin Surface Plating
Housing Type
Mounting Type
Connection Type
Footprint Type
Soldering Profile
Weight
Environmental Compliance - REACH Declaration
- RoHS Declaration
- SCIP Reference Number
–40°C to +70°C (without derating)
+100°C max.
–50°C to +125°C
3.3 %/K above 70°C
See application note: www.tracopower.com/overview/tes3wi
Natural convection (20 LFM)
On: 2.5 to 5.5 VDC or open circuit
Off: -0.7 to +0.8 VDC or short circuit
Refers to 'Remote' and '-Vin' Pin
5 mA max.
-0.4 mA max.
180 - 580 kHz (PFM)
300 kHz typ. (PFM)
Functional Insulation
1'500 VDC
1'000 MΩ min.
350 pF typ.
500 pF max.
1'000'000 h (MIL-HDBK-217F, ground benign)
Level 2 (J-STD-033C)
According to Cleaning Guideline
www.tracopower.com/info/cleaning.pdf
Plastic resin (UL 94 V-0 rated)
Phosphor Bronze (C5191)
Copper (1 - 3 µm)
Tin (7.5 µm min.), matte
Plastic Case
PCB Mount
SMD (Surface-Mount Device)
SMD24
Lead-Free Reflow Soldering (acc. J-STD-020E)
See application note: www.tracopower.com/info/reflow-soldering.pdf
8.8 g
www.tracopower.com/info/reach-declaration.pdf
REACH SVHC list compliant
REACH Annex XVII compliant
www.tracopower.com/info/rohs-declaration.pdf
Exemptions: 7a
(RoHS exemptions refer to the component
concentration only, not to the overall
concentration in the product (O5A rule).)
e33565be-1414-415c-805c-ff0333727756
Supporting Documents
Overview Link (for additional Documents)
www.tracopower.com/overview/tes3wi
All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated.
www.tracopower.com
September 20, 2023
Page 3 / 4
TES 3WI Series, 3 Watt
(0.039)
0.15 (0.006)
(0.40 ±0.02)
(0.08)
R0
2.0
.
(R
0. 5
02
)
0.5
1.0
(0.02)
9.7 (0.38)
10.2 ±0.5
Outline Dimensions
°
0-5
9.4
1 2 3
2.18
5.08
(0.200)
18.8 (0.74)
14.8 (0.58)
(0.41)
24.6 (0.97)
(0.086)
(0.37)
15 14 13
10.4
16.1 (0.63)
24 23 22
Ø1.5 (Ø 0.06) vent hole on bottom
10 11 12
17.78 (0.700)
side (for reflow soldering process)
5.08
(0.200)
All dimensions in mm (inches)
Tolerance: x.x±0.25 (x.xx±0.01)
Tolerance: x.xx±0.13 (x.xxx±0.005)
Pin tolerance: ±0.05 (±0.002)
32.3 (1.27)
Pinout
Pin
Single
Dual
1
–Vin (GND)
–Vin (GND)
2
–Vin (GND)
–Vin (GND)
3
Remote On/Off
Remote On/Off
10
NC
Common
11
NC
NC
12
NC
–Vout
13
+Vout
+Vout
14
NC
NC
15
–Vout
Common
22
NC
NC
23
+Vin (Vcc)
+Vin (Vcc)
+Vin (Vcc)
+Vin (Vcc)
24
NC: Not connected
1.6
5.08
17.78
5.08
(0.20)
(0.70)
(0.20)
(0.80)
20.2
(0.58)
14.8
(0.06)
(0.69)
17.5
(0.10)
2.7
2.54
(0.11)
Recommended Solder Pad Layout
27.94
(1.10)
Dimensions in mm (inch)
© Copyright 2023 Traco Electronic AG
Specifications can be changed without notice.
www.tracopower.com
Rev. September 20, 2023
Page 4 / 4
很抱歉,暂时无法提供与“TES 3-2412WI”相匹配的价格&库存,您可以联系我们找货
免费人工找货- 国内价格 香港价格
- 1+377.844191+45.14999
- 10+347.1286710+41.47968
- 25+335.6272025+40.10532
- 50+327.1813550+39.09610
- 100+318.95041100+38.11255
- 250+308.38796250+36.85041
- 500+225.58292500+26.95573
- 国内价格 香港价格
- 1+303.609801+36.27950
- 10+268.6833010+32.10600
- 20+257.8496020+30.81140
- 50+253.0684050+30.24010
- 100+248.27550100+29.66740
- 200+240.21730200+28.70450